NSG 4070 Windows software history

Date: 2011 Sept 05     Version: 1.1.2(Build:9)

changes:

  • RS232 speed 9600 Baud removed; not really necessary and to slow for file transfer
  • new file load indicator at immunity window start-up; helpful for long calibration files
  • changed USB-drivers included

fixes:

  • level field display error at Level Sweep and Level Sweep Spot Values, introduced with version V 1.1.2(Build: 8), removed

----------------------------------------------------------------------------------------------------------------------Date: 2011 April 06     Version: 1.1.2(Build:8)

fixes:

  • error at system calibration, introduced with version V 1.1.2(Build: 7), removed

----------------------------------------------------------------------------------------------------------------------
Date: 2011 March 09     Version: 1.1.2(Build:7)

changes:

  • help system changed to *.chm files for Win7 compatibility

fixes:

  • at graphical representation of *.mon files unit changed to dB, cursor values renamed from FPow: to Att:
  • write error of  *.cal and *.mon files in the Comment window (without NSG 4070) removed
  • measurement mode 4-6 or BCI are automatically activated at a click to the 8 measurement parameter keys

----------------------------------------------------------------------------------------------------------------------Date: 2011-02-09     Version: 1.1.2(Build:6)

changes:

  • threshold search step width also with absolute values (V, mA, dB) possible
  • monitoring output at test start also as constant High- or Low- Level available

----------------------------------------------------------------------------------------------------------------------

Date: 2011-01-04     Version: 1.1.2(Build:5)

changes:

  • user port outputs will be set at the start of calibration

----------------------------------------------------------------------------------------------------------------------

Date: 2010-10-13 Version: 1.1.2(Build:4)

changes:

  • negative values in "Additional Att." field now possible

----------------------------------------------------------------------------------------------------------------------

Date: 2010-07-27 Version: 1.1.2(Build:3)
changes:

  • two additional Level- Editor Tables for Ford standard EMC-CS-2009
  • temporary display of the eight storage keys parameter assignments
  • immunity test on one frequency possible

fixes:

  • English help file corrected
  • display error in the Level- Editor showing curves with linear steps on a logarithmic frequency axis removed
  • track bar test level changes by "Page Up/Down" can be applied with the "Enter" key
  • wrong error message display at system calibration removed

----------------------------------------------------------------------------------------------------------------------Date: 2010-05-06 Version: 1.1.2(Build:2)
changes:

  • graphical display of *.bmc files possible
  • an additional columns in the Level- Editor allow remote controlling of the NSG 4070 Amplifier Mode (int.; ext.; mix.)
  • reading and converting of new *.cfg files with synthesizer limitation possible;  converting of old files with PW:UP_FILES possible

fixes:

  • error in calculation of step numbers at "Number Per Decade" removed;
  • absent display of monitoring event "Power Limited" at test scan, graphical representation of test results and in the test report removed
  • indication of "Power Limited" as PWLim in the test report
  • IP-Address field limitation to two Numbers (only under special circumstances) removed

----------------------------------------------------------------------------------------------------------------------

Date: 2009-11-26     Version: 1.1.2(Build:1)

changes:

  • two additional columns in the Level- Editor allow remote controlling of MD 4070 and SW 4070 (also at Calibration); therefore a new file type *.bmc is implemented, to allow automatic switchover of the MD 4070
  • beginning with firmware V1.25 file transfer also possible about the RS232 or USB port; all limitations of this remote ports removed; this allows the remote controlling about an optical cable (hardware available)

fixes:

  • in generator window some errors in the Multi Channel Frequency Sweep mode removed
  • Threshold Search down now works correctly

----------------------------------------------------------------------------------------------------------------------

Date: 2009-07-24     Version: 1.1.1(Build:5)

changes:

  • program start in color OFF mode
  • program usable with 120 dpi (minor graphical inaccuracies are possible) 
  • for immunity test now frequency tables usable
  • additional usable delay for the scanning of the monitoring ports
  • additional monitoring output for simultaneously controlling of monitoring probe and rf-switch 
  • in generator window reduced frequency outputs at slider movement; leads to a synchronous freqouency tuning on NSG 4070 and prevents measurement interrupts of the programs power meters

fixes:

  • graphic cursor also on grid lines visible
  • transparent background on 16:9 screens removed
  • now date/time stamp of NSG4070 file remain unaffected when copied to the PC
  • cursor movement with keyboard limited to the visible frequency range
  • improvements in the auto range display

----------------------------------------------------------------------------------------------------------------------

Date: 2008-09-19     Version: 1.1.1(Build:4)

changes:

  • amplifier button for devices without amplifier not accessible

fixes:

  • copy function from PC to NSG4070 reactivated
  • error in frequency sweep with "Grid Absolute" removed
  • initialisation error in "Multi Channel" frequency sweep removed

----------------------------------------------------------------------------------------------------------------------

Date: 2008-07-16 Version: 1.1.1(Build:3)

changes:

  • DEMO modus for program demonstration
  • Level- and Table-Sweeps are also possible for BCI tests 
  • activatable, optical and acoustical signal at test end for operator alerting
  • additional, downwards threshold search mode 
  •  activatable, WinXP style program appearance 
  • program operation on 120 dpi screen possible (with little graphic inaccuracies)
  • display and print of test setup pictures
  • display and print of *.jpg files in the Files window
  • ASCII table output now with column headlines and readable monitoring events
  • additional placeholder for probe current in predefined, commend strings
  • additional Log-file parameters as frequency in Hz, comma separation and inverted PWM value
  • 3 separated reference memories for the power meters at the frequency sweep
  • measurement cursor movement about the 4 cursor keys
  • updated program help files

fixes:

  • error of truncated text labels removed
  • graphic print centred
  • graphic error after frequency zoom removed
  • error in the predefined, commend string output for analog voltage removed
    graphical error at display of curves below 100 kHz removed

----------------------------------------------------------------------------------------------------------------------
Date: 2008-04-16 Version: 1.1.0(Build:4)

changes:

  • print function at the graphical representation of test results and calibration curves

fixes:

  • error meassage at BCI test without monitoring probe at the end of the test
  • error meassage at the opening of the Immunity window after a 4-6 test with "Ask User" option removed

----------------------------------------------------------------------------------------------------------------------
Date: 2008-03-12 Version: 1.1.0(Build:3)


changes:

  • Short Key F4 and F5 for Start/Stop and Holt/Continue
    additional impuls on a Userport output at the start of a test (to Reset the EUT)
    additional, definable delay time for the start of the "Threshold Search". Allows the EUT a grater reaction time for the jump from the test level to the threshold search start level.

fixes:

  • ON/OFF switching of the NSG4070 at threshold search at the last test frequency removed

----------------------------------------------------------------------------------------------------------------------
Date: 2008-03-10 Version: 1.1.0(Build:2)


fixes:

  • switching off the NSG4070 after a level sweep
  • error after screen saver activation with windows decinal seperator "," removed 
  • wrong number of measurement steps with "Nomer per decade" in the generator window (causes a runtime error at a reference measurement in the generator window)

----------------------------------------------------------------------------------------------------------------------
Date: 2008-01-13 Version: 1.1.0(Build:1)

changes:

  • added BCI testing according to ISO 11452-4
  • ramp function for test level
  • BCI range sweep with new range-level-editor. Introducing new file typs for this sweep mode.
    Range definition file : *.blv
    Range calibration file : *.bcl
    Range test results : *.brs
  • All file are only usable on the PC and not on the NSG 4070 !
  • addded automatic threshold searching
  • configguring of the monitor outputs possible
  • 8 additional keys for storing and recalling of test parameter sets
  • initialising the global setup menu entrys (BCI and 4-6) with the actual test parameters
  • introduced a new ISO step whith, according to ISO 11451/2
  • definable comment strings with templates, for the slider and comment buttons in the Immunity window
  • COM port numbers up to 30 avalable
  • new frequency sweep mode in the Generator window for four port measurements with graphical representation
  • frequency synchron measurement recording of the 3 power meter cannals in to a *.log file
Direct entry: