Logo Teseq
formerly Schaffner Test Systems
WORLDWIDE
Choose your country:
 

Technical Note TN009

Last updated 1st May 2002

Title: Scope and Required Test Equipment for common RF commercial immunity standards

Applies to: CIS9942

International Immunity Standard IEC1000 or European Equivalent EN61000

International Immunity Standard IEC1000 or European Equivalent EN61000

Standard Scope

EN50082-1

All apparatus intended for use in domestic, commercial and light industrial environments for which no product-specific standards exist

EN50082-2

As above for the heavy industrial environment
IEC1000-4-2 Basic Standard: electrostatic discharge

EN61000-4-2

Air and contact test method
IEC1000-4-3 Basic standard: radiated RF field

EN61000-4-3

Screened chamber, TEM cell or stripline test methods
IEC1000-4-4 Basic standard: electrical fast transient bursts

EN61000-4-4

Direct injection or capacitive clamp test methods

IEC1000-4-6

Basic standard: conducted RF injection

EN61000-4-6

Voltage or current test methods

EN55020

Broadcast sound and TV receivers and associated equipment
Standard
Required test equipment

EN50082-1

EN61000-4-2

       

 

EN61000-4-3

       

EN61000-4-4

         

EN61000-4-6

   

   

EN55020

 

   

 

Signal generator, RF power amplifier

Anechoic chamber, Bilog antenna

TEM/GTEM cell or stripline

Current probe and/or CDNs

ESD Generator

EFT generator and capacitive clamp

Ground plane


 
Direct entry: