  • Telecom line surge testing
  • Complies with IEC/EN 61000-4-5
 

Teseq’s CDN 117 coupling-decoupling network enables convenient testing with surge pulses of 1.2/50 μs on data, signal or peripheral lines, as specified in many product standards. The test method, severity levels, permissible reaction of the EUT and specification of the coupling networks are included in IEC/EN 61000-4-5.

 
Parameter Value
Max operating voltage AC 250 V, DC 250 V
Max operating current 1.5 A
Ohmic resistance per path <2.5 Ω
 

Teseq’s CDN 118 coupling-decoupling network is designed for convenient surge testing of telecommunications equipment to IEC/EN 61000-4-5, which specifies a 1.2/50 μs or a 10/700 μs pulse. The CDN 118 includes the special decoupling network and coupling elements that are required for these tests.

 
Parameter Value
Max operating voltage AC 250 V, DC 250 V
Max operating current 0.5 A
Ohmic resistance per path 3 Ω