Back to home
Ametek
 

NSG 4060

Low frequency immunity test system

NSG 4060zoom
 
  • Signal generator and integrated power amplifier 15 Hz to 150 kHz
  • Meets IEC / EN 61000-4-16 in combination with NSG 4060-1
  • Meets IEC / EN 61000-4-19 in combination with CDND M316-2 for voltage and CT 419-5 for current testing
  • Meets IEC / EN 60255-26 Annex A in combination with CN 60255-26
  • Prepared test configurations for IEC / EN 61000-4-16 and IEC / EN 61000-4-19
  • 5.7” color display 
  • Multiple EUT monitoring options
 

The NSG 4060 is an EMC immunity test system for the frequency range 15 Hz to 150 kHz. It consists of a sine wave generator, power amplifier, EUT monitoring interfaces and different coupling units depending on the application, i. e. NSG 4060-1 for testing IEC / EN 61000-4-16 including short duration disturbance tests for DC, AC from 162/3 Hz to 200 Hz and test levels up to 300 V. Voltage testing according IEC / EN 61000-4-19 requires the combination with CDND M316-2. It includes the differential mode coupling and decoupling and the required 10 Ω impedance of the disturbance source. Current testing according IEC / EN 61000-4-19, e.g. testing electricity meters, requires the combination with CT 419-5.
The powerful and easy to use firmware makes the NSG 4060 independent from an external PC and control software, however it can also be remote controlled for system operation. Part of NSG 4060’s delivery is an USB-to-serial / optical converter which offers potential free remote control.

 

Technical specifications NSG 4060 in combination with NSG 4060-1

Application:

IEC 61000-4-16 edition 2.0, EN 61000-4-16:1998 / FprA3:2015

Frequency range Short duration test 1 s: DC, 162/3 Hz to 200 Hz
Sweep and continuous test: 13 Hz to 150 kHz
Output voltage Short duration test 1 s: 0.1 Vrms to ≥300 Vrms (max. 2 A), 0.1 Vrms to 100 V DC
Sweep and continuous test: 0.1 Vrms to ≥30 Vrms
Phase synchronisation:

Harmonic distortion: Short duration test: <10%
Sweep and continuous test: <1%
Rise and fall time of the DC output voltage at on / off switching:

between 1 to 5 μs

Output impedance:

50 Ω ±10%

 

Technical specifications NSG 4060 in combination with CDND M316-2

Application:

IEC 61000-4-19 edition 1.0, EN 61000-4-19:2015

Frequency range:

2 kHz to 150 kHz

Output voltage:

0.1 Vrms to ≥20 Vrms

Output impedance:

10 Ω ±30%

Harmonic distortion:

<5%

Pulse modulation

Modulation frequency range: 3 Hz to 10 kHz
Frequency resolution: 0.01 Hz
Duty cycle: 50%
Rise / fall time (10% / 90%): < 10 μs

 

Technical specifications NSG 4060 in combination with CT 419-5

Application:

IEC 61000-4-19 edition 1.0, EN 61000-4-19:2015
TR 50579:2012

Frequency range:

2 kHz to 150 kHz

Output current:

2 kHz to 30 kHz 0.1 A to ≥4 A
30 kHz to 150 kHz 0.1 A to ≥2 A

Harmonic distortion:

<5%

Pulse modulation:

Modulation frequency range: 3 Hz to 10 kHz
Frequency resolution: 0.01 Hz
Duty cycle: 50%
Rise / fall time (10% / 90%): < 10 μs

Output impedance:

 1 Ω ±30%

 

General specifications NSG 4060

Display:

640 x 480, 5.7” color

Output connector:

4 mm safety banana

User port:

D-Sub 15 pole with 4 TTL inputs and 4 TTL outputs
+12 V / 100 mA, -12 V / 100 mA, +5 V / 100 mA power supply

Monitoring input analog:

BNC socket, 0-24 V Ri=>15 kΩ, 6 mV resolution

Monitoring digital input:

BNC socket, 0 to 24 V via optical coupler Ri=1.5 k Ω, switching threshold approx. 2 to 3 V

Monitoring optical input:

optical fiber, HP versatile link HFBR0501 series 40 kBd

Sensor input:

ODU socket, 0 to 5 V Ri≥4 kΩ, 6 mV resolution

External modulation input:

BNC socket (prepared only)

RS232:

D-Sub 9 pole, up to 115200 Bd

RS232 optical:

Connector 2 x HFBRx523 socket for 1 mm fiber optic cable with length between 5 m and 30 m with 115200 Bd, for other distances 38400 Bd, max. 50 m

Mains input:

110 to 230 VAC 50 / 60 Hz, autoranging

Size (W x H x D):

45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)

Weight:

approx. 15 kg

Cardboard box:

60 cm x 55 cm x 37 cm, weight of cardboard box approx. 2.3 kg (empty)

 

General specifications NSG 4060-1 Extension Unit

Input / output connectors:

4 mm safety bananas

Size (W x H x D):

45 cm (19“) x 15 cm (3HU) x 37.5 cm

Weight:

approx. 35 kg

Packing case:

66 cm x 55 cm x 32 cm, approx. 10 kg (empty)

 

Technical specifications NSG 4060 in combination with NSG 4060-1 and NSG 4060-op1

Application:

IEC 61000-4-16 edition 2.0, EN 61000-4-16:1998 / FprA3:2015

Frequency range


Short duration test 1 s:

DC

Output voltage


Short duration test 1 s:

1 V to 330 V DC

Continuous test:

1 V to ≥30 V DC

Resolution:

0.01 V

Rise and fall time of the DC output voltage at on / off switching:

between 1 to 5 µs

Output impedance:

50 Ω ±10%

 

General specifications NSG 4060-op1

Mains input:

200 to 240 VAC 47 / 63 Hz

Size (W x H x D):

43 cm x 9 cm x 43 cm

Weight:

approx. 13 kg 

Datasheet

Support

Gallery

 
 
 
 

Imprint

AMETEK CTS GmbH
Sternenhofstr. 15
4153 Reinach, Switzerland
Tel.+ 41 61 204 41 00
marketing.cts@ametek.com

Managing Directors:
Manfred A. Bergsch
Astrid Wälchli Schreiber
VAT-ID: CHE-179.452.414
Register of companies: CH-280.4.015.069-3


 
 
By continuing to use the site, you agree to our Privacy and Cookie Policy.