  • EMC tests for vehicle components immunity to RF fields
  • Specified in EU directives 2004/104/EG, 2005/83/EG and 2009/0154 (COD)
  • 800 mm distance between the plates
 

The transversal electromagnetic mode which can be developped in the SL 150 strip line, provides the opportunity for doing EMC testing inside the strip line. The strip line is specified in EU directives 2004/104/EG, 2005/83/EG and 2009/0154 (COD). Frequency range and general settings are also described in ISO 11452‑1. The SL 150 allows testing electrical/electronic sub modules (EUB).

The SL 150 consists of two parallel metal plates. The EUT is arranged in the middle between these plates. The largest outer dimension of the EUT should not be more than 1/3 of the plate distance. The ground is on the lower plate and the isolated upper plate is supplied with RF energy. Between the plates, an electromagnetic field will be established. A typical test configuration consists of signal generator, power amplifiers, power meters and SL 150. To avoid interactions with the environment, the test should be run in an anechoic test chamber.

 
Parameter Value
Frequency range

10 kHz to 1000 MHz

Max. input power

100 W

Connector type

N, 50 Ω female

Typical CW Input power for 10 V/m

approx. 10 W (30 MHz to 500 MHz)

Distance between the plates

800 mm

Datasheet

 
 
 

Imprint

AMETEK CTS GmbH
Sternenhofstr. 15
4153 Reinach, Switzerland
Tel.+ 41 61 204 41 00
marketing.cts@ametek.com

Managing Directors:
Brian Huntsman
Astrid Wälchli Schreiber
VAT-ID: CHE-179.452.414
Register of companies: CH-280.4.015.069-3


 
 
By continuing to use the site, you agree to our Privacy and Cookie Policy.