Impedance stabilization network ISN T2A |
 |
- For use with one unshielded balanced pair
- CISPR 22/32 for Cat.3 and Cat.5
- Changeable pin-arrangements with RJ11 and RJ45
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
Impedance stabilization network ISN T4A |
 |
- For use with one or two unshielded balanced pairs
- CISPR 22/32 for Cat.3 and Cat.5
- Changeable pin-arrangements with RJ11 and RJ45
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
Impedance stabilization network ISN T8 |
 |
- For use with one, two, three, or four unscreened balanced pairs
- CISPR 22/32 for Cat.3 and Cat.5
- 1000 BaseT and PoE application
- Changeable pin-arrangements with RJ11 and RJ45
|
Impedance stabilization network ISN T8-Cat6 |
 |
- ISN T8 for cable category 6 (LCL 75/60 dB) and RJ45 connection
- For use with one, two, three, or four unscreened balanced pairs CISPR 22/32 for Cat.6
- 1000BaseT and PoE application
- Transmission bandwidth 250 MHz
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
Impedance stabilization network ISN ST08 |
 |
- For use with screened RJ45 connections
- Up to 8 lines/ 4 pairs
- Meets the requirements of CISPR 22/32
- Design given in figure D.11 of CISPR 22
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
Impedance stabilization network ISN S501 |
 |
- For use with coaxial lines
- BNC connectors
- Meets the requirements of CISPR 22/32
- Design given in figure D.9 of CISPR 22
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
CAS ISN, calibration kit for ISN T |
 |
- Meets CISPR 22/32 and CISPR 16-1-2
- Optional extensible for measurements on ISN T2 and ISN T8-Cat6
- Measurements for common mode impedance, phase angle, voltage division factor, decoupling attenuation (isolation) and longitudinal conversion loss (LCL)
|
CAS ISN-EXT-TRA, extension for transmission and crosstalk |
 |
- Extension for CAS ISN
- Measurements for transmission and crosstalk
- Suitable for cat.6 (250 MHz)
|
Magnetic fixture for ISN T2A, ISN T4A, ISN T8, ISN T8-Cat6 or CDN T8 |
 |
- Improvement of the ISN earth connection to steel surfaces
- Allows vertical positioning of the ISN (chamber wall)
- Easy positioning of the ISN in the setup
- Ruggedly designed
|
ISN for power line telecommunication (PLT) ISN PLT |
 |
- For use with Type 1 & 2 PLT devices
- Switchable LCL
- Conform with CISPR/I/301/CD
- Supplied with Coupling Unit
|
ISN for power line telecommunication (PLT) ISN PLT-A |
 |
- For asymmetric disturbance measurements on PLT devices
- Frequency range 1.6 to 30 MHz
- LCL >55 dB
- Conform with EN 50561-1
- Supplied with Coupling Unit
|